What’s Included
AM-530
9V(6F22) x1 battery installed
Test leads
Type-K Probe x 1
Velcro strap
Carrying case
Specifications
True-rms: Yes
AC Voltage: 400 mV, 4.000 V, 40.00 V, 400.0 V, 600 V +/- (1.0 % rdg + 3 LSD) @ 45 Hz to 400 Hz, 4 V to 400 V ranges
DC Voltage: 400 mV, 4.000 V, 40.00 V, 400.0 V, 600 V +/- (0.8% rdg + 1 LSD) @ 4 V to 400 V ranges
AC Current: 400.0 μA, 4000 μA, 40.00 mA, 400.0 mA, 4.000 A, 10.00 A +/- (1.2% rdg + 3 LSD) @ 400 μA to 400 mA ranges, 45 Hz to 400 Hz
DC Current: 400.0 μA, 4000 μA, 40.00 mA, 400.0 mA, 4.000 A, 10.00 A +/- (1.0% rdg + 2 LSD) @ 400 μA to 400 mA ranges
Frequency: 10 Hz to 10 MHz +/- (0.1% rdg + 4 LSD)
Resistance: 400.0 Ω, 4.000 kΩ, 40.00 kΩ, 400.0 kΩ, 4.000 MΩ, 40.00 MΩ +/- (1.0% rdg + 2 LSD) @ 4 kΩ to 400 kΩ ranges
Capacitance: 40.00 nF, 400.0 nF, 4.000 μF, 40.00 μF, 400.0 μF, 4000 μF +/- (3.0% rdg + 5 LSD) @ 400 nF to 40 μF ranges
Temperature: -40 ⁰F to 1832 ⁰F -40 ⁰C to 1000 ⁰C +/- (1.8% rdg + 6 ⁰F) @ >32 ⁰F to 212 ⁰F +/- (1.2% rdg + 3 ⁰C) @ >0 ⁰C to 100 ⁰C
Number of Temperature Inputs: Single Thermocouple