By Amprobe

Amprobe AM-530 True-rms Electrical Contractor Multimeter

Availability: Low stock: 6 left
SKU: AM-530
MFR#:
AM-530

Regular price $142.95
Regular price Sale price $142.95


Regular price $142.95
Regular price Sale price $142.95
The Amprobe AM-530 autoranging digital multimeter is the multimeter of choice for professional electrical contractors. The AM-530 is a True-rms digital multimeter so it accurately measures voltage on systems affected by harmonics. With its full menu of digital multimeter features, you can use it to: measure and verify the presence of voltage before connecting new equipment or performing repairs; run new wiring; check continuity of electrical connections; identify blown fuses; troubleshoot motors or check transformers. The CAT III 600 V safety rating provides an extra measure of safety for high voltage multimeter applications. Its built-in flashlight helps you see wire colors in the dark and “third hand” probe holder gives you an extra hand when you need it.

What’s Included
  • AM-530
  • 9V(6F22) x1 battery installed
  • Test leads
  • Type-K Probe x 1
  • Velcro strap
  • Carrying case
Specifications
True-rms: Yes
AC Voltage: 400 mV, 4.000 V, 40.00 V, 400.0 V, 600 V    +/- (1.0 % rdg + 3 LSD) @ 45 Hz to 400 Hz, 4 V to 400 V ranges
DC Voltage: 400 mV, 4.000 V, 40.00 V, 400.0 V, 600 V    +/- (0.8% rdg + 1 LSD) @ 4 V to 400 V ranges
AC Current: 400.0 μA, 4000 μA, 40.00 mA, 400.0 mA, 4.000 A, 10.00 A    +/- (1.2% rdg + 3 LSD) @ 400 μA to 400 mA ranges, 45 Hz to 400 Hz
DC Current: 400.0 μA, 4000 μA, 40.00 mA, 400.0 mA, 4.000 A, 10.00 A    +/- (1.0% rdg + 2 LSD) @ 400 μA to 400 mA ranges
Frequency: 10 Hz to 10 MHz    +/- (0.1% rdg + 4 LSD)
Resistance: 400.0 Ω, 4.000 kΩ, 40.00 kΩ, 400.0 kΩ, 4.000 MΩ, 40.00 MΩ    +/- (1.0% rdg + 2 LSD) @ 4 kΩ to 400 kΩ ranges
Capacitance: 40.00 nF, 400.0 nF, 4.000 μF, 40.00 μF, 400.0 μF, 4000 μF    +/- (3.0% rdg + 5 LSD) @ 400 nF to 40 μF ranges
Temperature: -40 ⁰F to 1832 ⁰F -40 ⁰C to 1000 ⁰C    +/- (1.8% rdg + 6 ⁰F) @ >32 ⁰F to 212 ⁰F +/- (1.2% rdg + 3 ⁰C) @ >0 ⁰C to 100 ⁰C
Number of Temperature Inputs: Single Thermocouple